My Cart

Chemiluminescent Substrate Solution (AE Marker)

Customer Reviews
Cat. No. / Size
Price
Qty
ABK-001-2L
$115.00
ETA of in-stock products:2 business days
Sub-Total$ 0

Product Details

  • ID
    Components
    Size
    ABK001-C01
    Trigger A (Oxidant solution)
    1 L
    ABK001-C02
    Trigger B (Enhancer solution)
    1 L
  • Product Overview

    The chemiluminescence substrate solution is a simple triggering reagent for acridinium ester (AE) fast light emission. Acridinium ester is the most commonly used for protein labeling and widely used in automated instruments because of its high sensitivity with detection limits in the attomole range. This product is suitable for acridinium ester labels on chemiluminescence technology, it is provided in two liquid buffer of Trigger A (Oxidant solution) and Trigger B (Enhancer solution) in each kit. When used, mix Trigger A and Trigger B in equal volume by 1:1, and light emission from acridinium esters is quite rapid and is essentially complete in <5s.

  • Application

    The chemiluminescence substrate solution is used to trigger acridinium ester labels to give a quite rapid light emission in chemiluminescence technology.

  • Storage

    4°C~30°C under sterile conditions for 12 months. Do not freeze.
    Product is shipped at ambient temperature.

Customers Also Viewed

Performance Data

  • Bioactivity-MPCLIA

     AE MPCLIA

    When used the Chemiluminescent Substrate Solution (AE Marker) (Cat. No. ABK-001) in a sandwich MPCLIA Assay for detection of Monoclonal Anti-Human CD3 Antibody, Mouse IgG2a (Clone: OKT3), premium grade. Immobilized 0.04 μg /Test of Biotinylated Human CD3E&CD3D Heterodimer Protein, His,Avitag&Tag Free (Cat. No. CDD-H82W6) to the Streptavidin-Magnetic Beads (recommended for MPCLIA) (Cat. No. MPC-A006, 20 μg beads/Test), incubated with 100 μL /Test of Monoclonal Anti-Human CD3 Antibody, Mouse IgG2a (Clone: OKT3), premium grade (Cat. No. CDE-M120a) at increasing concentration coupled to Anti-Mouse IgG-Acridinium ester(Cat. No. AMG-S163, 0.04 μg /Test). Detection was performed with sensitivity of 0.98 ng/mL in Magnetism particulate chemiluminescence immunoassay (MPCLIA) (KEYSMILE, SMART 6500S) (QC tested).

    Protocol

Customer Reviews
Writing Reviews

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
Contact Us

[North America]: +1 800-810-0816
[Switzerland]: +41 800 040 012
[Asia & Pacific]: +86 400-682-2521

[North America]: 1 Innovation Way, Newark, DE 19711, USA
[Switzerland]: ACRObiosystems AG, c/o Zug Dammstrasse Centre AG, Dammstrasse 19, 6300 Zug Switzerland